Abstract

A gas-chromatographic procedure is proposed for the determination of O-isobutyl S-2-(N,N-diethylamino)ethyl methyl phosphonothioate (mixed ester) at the maximum permissible level for the working area air (5 × 10–6 mg/m3) and at the safe reference level of impact for the community air (5 × 10–8 mg/m3). The procedure is based on trapping the mixed ester from air by a chemisorbent. Next, the analyte is extracted by hexane; transformed to O-methyl-O-isobutyl methyl phosphonate by silver nitrate in methanol; and, in the case of the working area air, the methanol solution of the derivative is chromatographed. In the determination of the mixed ester in the community air, a solution of O-methyl-O-isobutyl methyl phosphonate (dialkyl methyl phosphonate) in methanol is passed through a column with an adsorbent and transferred to the chromatographic system with a thermal desorption system. The relative error of the determination of the mixed ester in the working area and community air is no more than 28 and 40 rel. %, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.