Abstract

Abstract A gas chromatographic method is described for determining Monitor (0,S-dimethyl phosphoramidothioate) in a variety of crops. After extraction of the sample with ethyl acetate, the solvent is evaporated and an ether solution of the residue is passed through a silica gel column to remove interferences. Monitor is then eluted from the column with acetone and measured by gas chromatography, using a cesium bromide thermionic detector. The majority of standard recovery values ranged between 90 and 100% when samples were fortified at 0.05 to 0.1 ppm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.