Abstract

A GC method for the analysis of technical and formulated bifenthrin samples was evaluated in a collaborative study. Bifenthrin is determined by using a 50% (trifluoropropyl)-methylpolysiloxane wide-bore capillary column and flame ionization detector. Ten samples, consisting of four formulations and a technical material were analyzed by 12 collaborators using Youden pairs. The four formulation types included in this study were microemulsion (ME), wettable powder (WP), suspension concentrate (SC), and emulsifiable concentrate (EC). Variability in the analysis of two of the formulation types, SC and EC, was later found to be due to the noncommercial containers used to hold the test samples. Because of this, valid data could not be obtained for the EC and SC. For the two formulations for which valid data could be obtained, ME and WP, and the technical chemical, accuracy and variability results are typical of large data sets. For the technical chemical and the two formulations for which valid data were obtained, Official First Action is recommended.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.