Abstract
Gas bremsstrahlung is generated in high energy electron storage ring and accompanies the synchrotron radiation into the beamlines, where both strike the various components of the beamline. In this paper, radiation shielding calculations for secondary gas bremsstrahlung are performed for the First Optics Enclosure (FOE) of X-ray powder diffraction (XPD) beamline of the Iranian Light Source Facility. Dose equivalent rate (DER) calculations are accomplished using FLUKA Monte Carlo code. A comprehensive study of DER distribution at the back wall, sides and roof are given.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.