Abstract

The EGS4 electron-photon Monte Carlo code has been used to study the characteristics of the bremsstrahlung x rays generated from the interaction of circulating electrons with the residual gas in accelerator storage rings. Gas bremsstrahlung dose rates are given for various opening angles as a function of the electron beam energy ranging from 0.5-10 GeV. Photon and neutron dose rates, generated from various devices struck by gas bremsstrahlung in a synchrotron radiation beamline, are also presented along with the photon spectral and transmission results. The EGS4-predicted results are found to be in basic agreement with the measurements made at the Stanford Synchrotron Radiation Laboratory. Figures, equations, and a simple method useful for the photon-neutron shielding design for beamlines are provided.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.