Abstract

Bed collapsing experiments were carried out in a cold-air transparent column 192 mm in diameter and 2 m high. Typical Fluid Catalytic Cracking (FCC) catalyst with a mean particle size of 76 μm and a density of 1400 kg/m 3 was used. Both single and double-drainage protocols were tested. The local pressure drop and bed surface collapse height were acquired throughout the bed settling. Typical results were found regarding dense phase voidage of a fluidised bed and the bed surface collapse velocity. In addition, bubble fraction was calculated based on the collapse curve. Experimental results showed that windbox effect is significantly reduced compared to previous works since the volume of air within the windbox was reduced. The comparison of single/double-drainage protocols revealed a new period in the defluidisation of Geldart-A particles concerning gas compressibility. Through the temporal analysis of local pressure drop, the progress of the solid sedimentation front from bottom to top was determined, analysed and modelled.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.