Abstract

Given the operational constraints of aerospace ground equipments (AGE), the non‐thermal plasma discharge (NTPD) has been identified as a promising technology for their NOx removal. As part of a program to optimize an NTPD system for this particular application, an investigation of the effect of discharge gap spacing on the electrical and chemical processes that occur in NTPDs was initiated. A number of experiments were performed to examine how the gap spacing affects the NO removal efficiency, discharge characteristics, and chemical reactions in a NTPD device. Gap spacings ranging from 0.8 to 4.0 mm were investigated in this study. An optimum gap spacing for NO removal was observed at approximately 2 mm and, based on the experimental data, a physical explanation for the optimum was developed. The experiments, results and conclusions are discusssed in detail in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.