Abstract

A radioisotope system has been developed to locate groups of termite-damaged sleepers during continuous scans of a railway track. It depends on measuring the intensities of collimated beams of caesium-137 γ-rays backscattered from within the sleeper. The detected intensity varies with the amount of termite damage (i.e. voidage). Variations in intensity caused by changes in the density of sound sleepers are minimised by the geometrical arrangement of source, shields and detector. The Atomic Voidage Detector (AVD) has been tested in field trials on the Newman to Port Hedland railway, Western Australia. Four separate groups of termite-damaged sleepers were located and examined. The lower limit of detectable voidage depends mainly on the scanning speed and distribution of voids within the sleeper, and is very approximately 8% voidage at 10.7 km/h and 5% at 2.7 km/h.