Abstract
Installing a maze on the corridor reduces much shielding materials in shielding door at the end of the pathway. In this study, gamma transmission was measured along single-, double-, and triple-bend mazes, which were applied to nondestructive test workplace by Monte Carlo method. In the facility using 192Ir 1.85TBq, the lengths of corridors to reduce the effective dose under the limitation without shielding door were 10 and 6m in double- and triple-bend mazes, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.