Abstract

A gamma-ray transmission gauge was applied for the measurement of the interzone-layer parameters in an extraction tower. The resolving power'' function of the gauge was used to obtain the optimum design parameters, such as gamma-ray energy, source-to-detector distance, and gauge location on the separation tower. Results from a prototype gauge operated on a furfural extraction tower in the lubrication oil industry are presented and discussed. The mathematical model described offers guidelines for analyzing similar gauging problems. (auth)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.