Abstract
A survey of gamma exposure in dwellings of Campania region, southern Italy has been performed using Thermo Luminescent Dosimeters (TLD). In each dwelling TLDs were exposed for six months in the room where the inhabitant spent most of their time, generally the bedroom or living room. The arithmetic mean was found to be 264 ± 111 nGy/h, after the subtraction of the cosmic contribution. The effects of building materials and geographic location were also examined. Using UNSCEAR model, the annual effective dose due to indoor gamma radiation was evaluated and it was found to be 1.3 mSv/y, that is higher than Italian national average of 0.4 mSv/y.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.