Abstract

Gamma-densitometry tomography (GDT) experiments have been performed to measure gas holdup spatial variations in two bubble columns: a 0.19 m inside diameter Lucite column and a 0.48 m inside diameter stainless steel vessel. Two-phase air/water flows were examined. Horizontal scans at one vertical position in each column were made for several air flow rates. An axisymmetric tomographic reconstruction algorithm based on the Abel transform has been used to calculate the time-averaged gas holdup radial variation. Integration of these profiles over the column cross section has yielded area-averaged holdup results, which have been compared with volume-averaged gas holdups determined from differential pressure measurements and from the rise in the air/water interface during gas flow. The results agree reasonably well.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.