Abstract

We present results for the CMS-RPC sensitivity to gamma rays which were simulated with GEANT4 Monte-Carlo Code. The simulations were performed as a function of gamma energy in a range from 0.007 to 1000 MeV. In order to evaluate the γ -induced rates in the CMS muon system, the gamma spectra expected in the CMS endcap and barrel regions were taken into account. The estimated rates induced by an isotropic gamma source in the ME1, ME2, ME3, and ME4 were 138.0, 42.0, 29.0, and 28.0 Hz/cm 2 , respectively, when the GEANT4 standard electromagnetic package was used for the simulations. Whereas, the hit rates estimated for the MB1 and MB4 stations were ∼ 0.4 and 1.26 Hz/cm 2 , respectively, when the same gamma-ray source and the same GEANT4 package were employed for the simulatiom.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.