Abstract

In the present work, several commonly used aluminum alloys were investigated for their protective properties against gamma radiation. The gamma transmission technique was used to study the gamma attenuation behavior of the alloys. Cs-137 (0.662 MeV) and Co-60 (1.25 MeV) gamma radioisotope sources, which have relatively medium and high gamma energy levels, were used as gamma sources. The linear and mass attenuation coecients of the aluminum alloys were measured. The mass attenuation coecients of the samples were compared with the theoretical values which were calculated using XCOM computer code. The dierence between the experimental and theoretical values was below 5%. In addition half-value layer (HVL) values for the studied aluminum alloys were calculated using the linear attenuation coecients. The attenuation coecients of the dierent aluminum alloys were compared. The biggest HVL was observed for 1050 alloy, for both gamma isotope sources, which means the smallest gamma attenuation capability among the studied alloys. It is concluded that the alloys were applicable for the gamma radiation shielding applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.