Abstract
BackgroundCoronary computed tomography angiography (CCTA) offers non-invasive diagnostics of the coronary arteries. Vessel evaluation requires the administration of intravenous contrast. The purpose of this study was to evaluate the utility of gadolinium-based contrast agent (GBCA) as an alternative to iodinated contrast for CCTA on a first-generation clinical dual-source photon-counting-detector (PCD)-CT system.MethodsA dynamic circulating phantom containing a three-dimensional-printed model of the thoracic aorta and the coronary arteries were used to evaluate injection protocols using gadopentetate dimeglumine at 50%, 100%, 150%, and 200% of the maximum approved clinical dose (0.3 mmol/kg). Virtual monoenergetic image (VMI) reconstructions ranging from 40 keV to 100 keV with 5 keV increments were generated on a PCD-CT. Contrast-to-noise ratio (CNR) was calculated from attenuations measured in the aorta and coronary arteries and noise measured in the background tissue. Attenuation of at least 350 HU was deemed as diagnostic.ResultsThe highest coronary attenuation (441 ± 23 HU, mean ± standard deviation) and CNR (29.5 ± 1.5) was achieved at 40 keV and at the highest GBCA dose (200%). There was a systematic decline of attenuation and CNR with higher keV reconstructions and lower GBCA doses. Only reconstructions at 40 and 45 keV at 200% and 40 keV at 150% GBCA dose demonstrated sufficient attenuation above 350 HU.ConclusionCurrent PCD-CT protocols and settings are unsuitable for the use of GBCA for CCTA at clinically approved doses. Future advances to the PCD-CT system including a 4-threshold mode, as well as multi-material decomposition may add new opportunities for k-edge imaging of GBCA.Relevance statementPatients allergic to iodine-based contrast media and the future of multicontrast CT examinations would benefit greatly from alternative contrast media, but the utility of GBCA for coronary photon-counting-dector-CT angiography remains limited without further optimization of protocols and scanner settings.Key PointsGBCA-enhanced coronary PCD-CT angiography is not feasible at clinically approved doses.GBCAs have potential applications for the visualization of larger vessels, such as the aorta, on PCD-CT angiography.Higher GBCA doses and lower keV reconstructions achieved higher attenuation values and CNR.Graphical
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.