Abstract

The natural cooling capacity and flow field in relatively small electronic equipment were studied. A channel model was used as an experimental model of electronic equipment. The channel model has two vertical copper walls modeling the printed circuit boards and two transparent walls modeling the casing walls. The width between the copper walls was varied from 10mm to 15mm. Velocity distributions in the channel were quantitatively measured using a particle image velocimetry (PIV). Thermal resistance is strongly influenced by the ratio of heating energy at the walls. Velocity distributions become asymmetric depending on the channel width and the heating energy ratio.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.