Abstract

As heat generation increases in CPUs and other small electronic devices, more miniaturized and efficient cooling technology has been required. In this study the authors investigated combination of impinging flow and high-carbon alcohol aqueous solutions in mini tube. The authors performed experiments and compared heat-transfer characteristics about cooling methods and working fluids. T-junction tube made of quartz glass realized the impinging flow. The flow tube has a circle cross section, and a diameter was 2.0 mm. They adopted pure water and butanol aqueous solutions for working fluids. Concentration level of butanol aqueous solutions was 1.50wt%, 3.00wt%, 4.50wt%, and 7.15wt%. It was found from the experimental results that liquid film of the butanol aqueous solutions extend in a direction toward high-temperature region and the butanol aqueous solutions gave higher cooling ability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.