Abstract
Objective: To determine blood culture contamination rates, and display with a g-chart.Materials and Methods: The medical records of patients, from whom blood cultures were obtained in a university hospital, during January and December 2019 were retrieved and reviewed for contamination. The Center for Disease Control and Prevention (CDC) criteria were used to classify the blood culture results. The contamination rates were illustrated with a g-chart.Results: We identified 331 false-positive blood cultures, among 32,961 cultured specimens; yielding a contamination rate of 1.0% (95%CI = 0.9% – 1.1%). The highest contamination events occurred in the Emergency department (49.2%), Pediatric ICU (5.2%) and Neonatal ICU (4.8%), respectively. The most common commensal bacterial genus were Staphylococcus coagulase negative (67.1%), Bacillus spp. (10.2%) and Corynebacterium spp. (7.6%), correspondingly. The g-charts could identify 14 abnormal variations, in 41 locations.Conclusion: The contamination rates found were within ranges of other reports. G-charts are simple to construct, easy to interpret and sensitive for detection of real time epidemics.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.