Abstract
This paper deals with active noise control (ANC) in an enclosure on a broadband frequency range. It aims to compare two control strategies: (i) an adaptive control approach namely FxLMS control, (ii) a robust H∞ control, in the SISO (single input single output) case. Only feedback scheme is considered and disturbance sources are assumed to be unknown. For the aim of a fair comparison focusing on the same frequency range of attenuation, a new FxLMS algorithm with a weighting filter is proposed. Finally, achievable performances of each control are analyzed through simulation and experimental results driven on an instrumented setup.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.