Abstract

Presented are the results of 99mTc and 101Tc production via neutron irradiation of natural isotopic molybdenum (Mo) with epithermal/resonance neutrons. Neutrons were produced using a deuterium-deuterium (D-D) neutron generator with an output of 2 × 1010 n/s. The separation of Tc from an irradiated source of bulk, low-specific activity (LSA) Mo on activated carbon (AC) was demonstrated. The yields of 99mTc and 101Tc, together with their potential use in medical single-photon emission computed tomography (SPECT) procedures, have been evaluated from the perspective of commercial production, with a patient dose consisting of 740 MBq (20 mCi) of 99mTc. The number of neutron generators to meet the annual 40,000,000 world-wide procedures is estimated for each imaging modality: 99mTc versus 101Tc, D-D versus deuterium-tritium (D-T) neutron generator system outputs, and whether or not natural molybdenum or enriched targets are used for production. The financial implications for neutron generator production of these isotopes is also presented. The use of 101Tc as a diagnostic, therapeutic, and/or theranostic isotope for use in medical applications is proposed and compared to known commercial nuclear diagnostic and therapeutic isotopes.

Highlights

  • Helmholtz-Zentrum Dresden–Rossendorf (HZDR), Institute of Resource Ecology, Bautzner Landstraße 400, Abstract: Presented are the results of 99m Tc and 101 Tc production via neutron irradiation of natural isotopic molybdenum (Mo) with epithermal/resonance neutrons

  • The liquid ammonium heptamolybdate (AHM) sample was irradiated with neutrons produced by an Adelphi DD110M neutron generator

  • We demonstrate the production of 99 Mo/99m Tc and 101 Mo/101 Tc via neutron bombardment of an aqueous target of natural Mo

Read more

Summary

Introduction

Helmholtz-Zentrum Dresden–Rossendorf (HZDR), Institute of Resource Ecology, Bautzner Landstraße 400, Abstract: Presented are the results of 99m Tc and 101 Tc production via neutron irradiation of natural isotopic molybdenum (Mo) with epithermal/resonance neutrons. Neutrons were produced using a deuterium-deuterium (D-D) neutron generator with an output of 2 × 1010 n/s. The yields of 99m Tc and 101 Tc, together with their potential use in medical single-photon emission computed tomography (SPECT) procedures, have been evaluated from the perspective of commercial production, with a patient dose consisting of 740 MBq (20 mCi) of. Neutron generator system outputs, and whether or not natural molybdenum or enriched targets are used for production. The financial implications for neutron generator production of these isotopes is presented. Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call