Abstract

We give a theoretical overview of non-fading infrared stimulated luminescence (IRSL) signals in feldspars, followed by intercomparison of potential methods on some sediment extracts. We observe that a more stringent thermal wash on its own is not effective in obtaining a more stable signal, suggesting that the higher the stimulation temperature in post IR-IRSL methods, the greater the ability to access distant electron hole pairs. We further find that the delayed off-time signal in time-resolved IRSL has immense potential for sampling non-fading signal and should be explored further; this signal also appears to be well reset in nature and avoids unwanted thermal transfer effects in comparison to the post IR-IRSL signal measured at 290 °C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.