Abstract

A new method for measurement of the lifetime of excess carriers in semiconductors is described. Using a steady light source and measuring changes in microwave power absorption as a function of position of the sample in a waveguide, bulk lifetime can be determined. Measurements described here were made at 9600 mc. The new technique offers the following advantages: First, the method does not require electrode attachments, thus making the preparation of the samples less difficult and the actual experiment less subject to error due to non-ohmic contacts. Second, the effects of surface recombination are made less important, thus giving a greater assurace of the evalaution of bulk lifetime.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.