Abstract

We investigate the fundamental spatial resolution of an x-ray pore optic as a function of the pore dimensions, the photon energy, and the focal length. We achieve this by calculating the shape of the focal spot, using diffraction integrals such that the half-energy width is determined. Quantitative results are presented for the X-Ray Evolving Universe Spectroscopy (XEUS) telescope, showing that a resolution of better than 2 arc sec half-energy width is possible by use of an optic with pore sizes of approximately 0.5 mm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.