Abstract

SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas has been widely used in electrical power equipment such as circuit breakers and transformers due to its superior insulation and interruption characteristics. However since 1997, SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas has been designated a greenhouse gas subject to emission restrictions at COP3 (The 3rd session of the Conference Of the Parties to the United Nations Framework Convention on Climate Change) so a new insulating gas is needed as a substitute for SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> gas. This research considers the use of high-pressure CO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> gas as an insulator while stressing the environment aspects. Fundamental insulation data for the insulating gas acquired supposing gas insulated switchgears (GIS) consists of; (1) insulation breakdown characteristics under clean conditions and, (2) insulation breakdown characteristics with metallic particle contamination. The parameters in this case were assumed from an actual apparatus viewpoint, to be a high gas pressure up to 2.0 MPa, an electrode size capable of determining the surface area effect, the electrode surface roughness, and metallic particle length, etc. at the base electrode of the 72 kV GIS. As a result, experiments using these parameters revealed insulation characteristics for high-pressure CO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> gas and that negative lightning impulse decided the insulation design, as well as the present SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> GIS. The need for taking measures to suppress PD under AC voltage and also the need for restricting metallic foreign particles around the central conductor and insulating spacer were recognized

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.