Abstract

The streaming current detector, or SCD, measures the streaming current created in a closed-end cylinder due to particles attached to cylinder and piston walls. The device is used in water and wastewater treatment applications for monitoring or automatic feedback control of coagulant or conditioner dosages. This paper reviews some aspects of proper SCD usage, and then provides an improved theoretical description with experimental validation, and a means for instrument standardization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.