Abstract

Micro gas turbine systems have been developed for a portable power supply. In this study kerosene sprays with pre-vaporized system for the ultra-micro gas turbine combustor were tested. Fundamental characteristics of the kerosene spray with fuel vaporization on a hot wall were investigated experimentally. A model combustor of ultra-micro gas turbine was used for combustion test of kerosene spray. In the combustion test, an extension tubes were set at the exits of fuel injectors for the enhancement of pre-vaporization of the kerosene spray. The effect of the extension tube on flame stability was discussed. As a result, the blow off limit became wider when the extension tube was set at fuel nozzle exit.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.