Abstract

Here we present our latest efforts in the development of functionalized carbon reinforcement structures (FCSs). FCSs are textile based carbon structures that are functionalized with optical fibre sensors and are designed for the reinforcement as well as structural health monitoring (SHM) of concrete composites. A schematic of a FCS is shown in Fig. 1a. In this example, the FCS contains an optical glass fibre to measure distributed strain profile using the Optical Frequency Domain Reflectometry (OFDR) technique as well as two Fibre Bragg Grating (FBG) sensors to determine local strain and strain direction. The fabrication technique to manufacture FCS has been developed at the Saxon Textile Research Institute (STFI) in Chemnitz, Germany, and the fabrication of the FCS involve embroidering of the carbon fibre filaments and optical glass fibres simultaneously on a polyvinyl alcohol (PVA) nonwoven substrate [1]. PVA was chosen as an embroider substrate since it can be easily removed by dissolving it in hot water and the dissolved PVA further stabilizes the FCS. A manufactured FCS that is embedded in a custom-made concrete block in order to evaluate the sensor performance of the FCS is illustrated in Fig. 1b. After the concrete was set, the concrete blocks containing the FCS were installed in a three point bending test rig (Fig. 1c) and the load transfer from the concrete to the FCS was observed using the integrated optical fibre sensors. In Fig. 1d, the response of the FBG sensor inside the FCS in response to the applied load is illustrated for three consecutive load cycles. As can be seen, the FBG sensor is able to detect the load cycles with a sensitivity of 0.44 nm/% as well as a relatively low hysteresis of 0.011% [2]. Moreover, as indicated in Fig. 1e, four strain peaks were detected using the OFDR during the three point bending test. The four strain peaks results from the integration of the optical fibre in a meander shape (see Fig. 1a) and thus the same optical glass fibre experiences along its length the same load at four different positions. Furthermore, the different magnitudes of the four strain peaks at different time stamps corresponds to the increase in applied load when the concrete block was subjected to the three point bending test [2]. Therefore, the experiments verify that the developed FCS can be applied to monitor spatial strain profiles with a relatively high sensitivity and low hysteresis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call