Abstract

BackgroundThe number of prosthesis brands used for hip replacement has increased rapidly, but there is little evidence on their effectiveness. We compared patient-reported outcomes, revision rates, and mortality for the three most frequently used brands within each prosthesis type: cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed), and hybrid (Exeter V40 Trilogy, Exeter V40 Trilogy, and CPT Trilogy).Methods and FindingsWe used three national databases of patients who had hip replacements between 2008 and 2011 in the English NHS to compare functional outcome (Oxford Hip Score (OHS) ranging from 0 (worst) to 48 (best)) in 43,524 patients at six months. We analysed revisions and mortality in 187,201 patients. We used multiple regression to adjust for pre-operative differences. Prosthesis type had an impact on post-operative OHS and revision rates (both p<0.001). Patients with hybrid prostheses had the best functional outcome (mean OHS 39.4, 95%CI 39.1 to 39.7) and those with cemented prostheses the worst (37.7, 37.3 to 38.1). Patients with cemented prostheses had the lowest reported 5-year revision rates (1.3%, 1.2% to 1.4%) and those with cementless prostheses the highest (2.2%, 2.1% to 2.4%). Differences in mortality according to prosthesis type were small and not significant (p = 0.06). Functional outcome varied according to brand among cemented (p = 0.05, with Exeter V40 Duration having the best) and cementless prostheses (p = 0.01, with Corail Pinnacle having the best). Revision rates varied according to brand among hybrids (p = 0.05, with Exeter V40 Trident having the lowest).ConclusionsFunctional outcomes were better with cementless cups and revision rates were lower with cemented stems, which underlies the good overall performance of hybrids. The hybrid Exeter V40 Trident seemed to produce the best overall results. This brand should be considered as a benchmark in randomised trials.

Highlights

  • Total hip replacement (THR) has proved to be a highly effective intervention to alleviate pain and improve function in patients with osteoarthritis

  • Functional outcomes were better with cementless cups and revision rates were lower with cemented stems, which underlies the good overall performance of hybrids

  • There has been a proliferation of different brands

Read more

Summary

Introduction

Total hip replacement (THR) has proved to be a highly effective intervention to alleviate pain and improve function in patients with osteoarthritis. Cementless attachment for the metal stem, the cup or both components has grown in popularity over fixation with cement [2]. Prostheses with a cementless stem and cup are the most popular type in many countries [3,4,5,6,7]. The ten most frequently used combinations of stem and cup brands covered nearly half of all THRs undertaken. We compared patient-reported outcomes, revision rates, and mortality for the three most frequently used brands within each prosthesis type: cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed), and hybrid (Exeter V40 Trilogy, Exeter V40 Trilogy, and CPT Trilogy)

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.