Abstract

Introduction and aimsThere is paucity of prospective studies on conversion total hip arthroplasty (CTHA) for failed proximal femoral nailing. The objective of this study is to evaluate the functional outcome of CTHA using extensively porous coated distal loading stem for failed proximal femoral nailing. Patients and methodsFifteen consecutively operated patients for failed proximal femoral nail treated with single stage procedure of nail extraction and CTHA were included in this prospective observational study. All patients received metal-on-polyethylene bearing with uncemented press-fit acetabular cup (Pinnacle cup; DePuy, Warsaw [IN], USA) and extensively porous coated distally loading revision stem (Solution stem; DePuy, Warsaw [IN], USA). All patients were assessed preoperatively and postoperatively at one, three, six and more than twelve months using the Harris Hip Score (HHS). The responsiveness of HHS was assessed using Effect Size (ES) and Standardised Response Mean (SRM). ES and SRM >0.8 indicates adequate responsiveness. ResultsThe mean duration of follow-up was 16.9 months for the overall cohort (SD: 7.9; range: 6–28 months). The mean preoperative HHS was 32 ± 6.1, the mean HHS at six months follow-up was 89.7 ± 4.0 and the mean HHS at final follow-up of atleast one year was 93.7 ± 3.0. There was a statistically and clinically significant improvement in the HHS from preoperatively to final follow-up postoperatively (p < 0.0001). At the final follow-up, twelve patients (80%) had an excellent outcome and three patients (20%) had a good outcome as per HHS grading. The ES was 9.87 and the SRM was 8.86 thereby suggesting adequate responsiveness. One patient developed surgical site infection and another patient developed dislocation. Both were successfully treated and subsequently the patients made uneventful recovery. None of the patients required revision surgery. ConclusionHHS has adequate responsiveness for assessing the functional outcome of CTHA. We recommend the use of an uncemented cup and uncemented extensively porous coated, distal loading stem for failed PFN fixation in intertrochanteric hip fractures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.