Abstract

Many studies have used functional optical zone (FOZ) as a measure to compare different refractive laser treatment modalities. However, to our knowledge, no study has compared wavefront- optimized (WFO) and wavefront-guided (WFG) laser in situ keratomileusis (LASIK) using FOZ. We compared the FOZ after WFO versus WFG LASIK in patients with myopia and myopic astigmatism. In this prospective comparative study, we included 100 myopic eyes of 50 patients with or without astigmatism. They were divided into two groups according to the platform used: WFO or WFG femtosecond LASIK. Using Holladay's equivalent keratometry reading (EKR) report of Pentacam HR, FOZ was defined as a zone centered on the pupil center with a standard deviation (SD) of 0.5 D, around the mean EKR. The differences in FOZ between the two platforms were analyzed at 3 months postoperatively. Visual acuity, refractive error, corneal asphericity (Q-value), and root mean square of higher-order aberrations (RMS for HOAs) were evaluated and compared. The mean (SD) of patient age was 26.64 (5.67) years. The preoperative characteristics of the two groups were comparable (all P > 0.05). The intended optical zone (IOZ) was 6 mm in both groups. The mean laser ablation depth was significantly greater in the WFG group (18 µm per D) than in the WFO group (16 µm per D) (P = 0.035). At 3 months postoperatively, the mean (SD) of FOZ diameter was 4.32 (0.94) mm (71.99% [15.68%] of intended optical zone) in the WFO group and 4.16 (1.13) mm (69.33% [18.78%] of intended optical zone) in the WFG group, with no significant difference between the two groups (P = 0.622). The change in corneal asphericity was greater in the WFG group than in the WFO group (P = 0.034). Postoperative mean corrected and uncorrected distance visual acuity, manifest refraction, and RMS for HOAs showed no significant difference between the two groups (all P > 0.05). We found that WFG LASIK resulted in greater ablation depth and change in corneal asphericity than WFO LASIK at 3 months postoperatively. However, there was no significant difference in FOZ diameter, refractive error, and RMS for HOAs between the two groups. Further research is needed to confirm these findings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.