Abstract

Polymeric foams tailor-made of polyvinylpyrrolidone (PVP) and carboxymethylcellulose/oxidized 6-carboxycellulose (CMC07/OC) composite were proposed as suitable sorbents for the collection and analysis of dried blood spots (DBSs). The PVP and CMC07/OC foams were easy to prepare, enabled collection of minute volumes of capillary blood, and blood drying at ambient temperature. The resulting foams were prepared as small porous discs with uniform dimensions (approx. 6 × 3 mm) and were fully soluble in aqueous solutions. The DBSs were formed in standard capillary electrophoresis (CE) vials fitted with the soluble foam discs and enabled the direct in-vial DBS processing and at-line analysis by CE. The DBSs were pretreated with a simple process, which involved a complete dissolution of the foam disc in an acidic solution and a simultaneous hollow fiber liquid-phase microextraction (HF-LPME) in one step. The complete solubility of the foam disc with the DBS served for a quantitative transfer of all blood components into the eluate and a nearly exhaustive HF-LPME of target analytes, whereas the blood matrix and the polymeric foam components were efficiently retained by the organic solvent impregnated in the walls of the HF. The suitability of the PVP and CMC07/OC foams for the collection and the direct analysis of DBSs was demonstrated by the HF-LPME/CE determination of model acidic drugs (warfarin, ibuprofen, naproxen, ketoprofen, and diclofenac) at therapeutically relevant concentrations. Repeatability of the analytical method was better than 8.1% (RSD), extraction recoveries ranged from 70 to 99% (for PVP foam), calibration curves were linear over two orders of magnitude (R2 higher than 0.9991), and limits of detection were less than 44 μg/L (for concentrations in undiluted capillary blood). The soluble polymeric foams exhibited non-significant variations in analyte concentrations for DBSs prepared from blood samples with different hematocrit levels and for aged DBSs (less than 9.2%), moreover, they outperformed standard DBS sampling devices in terms of sample pretreatment time and extraction recovery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.