Abstract

Advances in flexible and hybrid electronics promote increasing demands for wearable sensors in personal health, monitoring, and diagnostic medical gadgets. Conventional wearable devices rely on electronics based on rigid substrates and components with limited conformity to user skin. In this work, we report a fully integrated, stretchable wireless electrocardiography (ECG) system developed on highly elastic, ultra-thin ( 100 μm) thermoplastic polyurethane (TPU) film without any rigid or flexible interposer. Moreover, the circuit layout printing and component assembly are carried out through sheet-to-sheet (S2S) process directly on TPU film. This study utilizes both experimental reliability tests coupled with data acquired from finite element modeling (FEM) to assess performance and failure of the device under tensile loading. In such a complex system assembly, FEM simulation not only provides insights on the overall electromechanical performance of the device, but also facilitates localization of the failure points which are difficult to access for visual inspection. The performance of the device is also evaluated through controlled uniaxial cyclic strain at 5% and 10% elongation. The durability test shows that the assembled device can stay functional over hundreds of deformation cycles, suggesting that direct assembly of conventional components on stretchable substrate represents a promising approach for fully integrated stretchable devices, which is a step toward scalable manufacture of wearable stretchable electronics through high-throughput manufacturing processes.

Highlights

  • W EARABLE sensors receive increasing attention, as advances in integration of hybrid electronics can realize extremely conformal wearable skin patches on flexibleManuscript received September 18, 2020; revised April 30, 2021; acceptedMay 11, 2021

  • This study mainly focuses on sheet-to-sheet (S2S, known as sheet-fed) processing of the stretchable device and its electromechanical performance over cyclic strain at 5% and 10% elongation

  • The durability of the devices was evaluated with 5% and 10% uniaxial cyclic strain

Read more

Summary

Introduction

W EARABLE sensors receive increasing attention, as advances in integration of hybrid electronics can realize extremely conformal wearable skin patches on flexibleManuscript received September 18, 2020; revised April 30, 2021; acceptedMay 11, 2021. W EARABLE sensors receive increasing attention, as advances in integration of hybrid electronics can realize extremely conformal wearable skin patches on flexible. Manuscript received September 18, 2020; revised April 30, 2021; accepted. Date of publication May 21, 2021; date of current version. Grant 3087/31/2018 and Grant 2947/31/2018 and in part by the Academy of Finland [utilized the Printed Intelligent Infrastructure (PII-FIRI)] under Grant. Recommended for publication by Associate Editor P.

Objectives
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.