Abstract

Orthognathic surgery enables patients with severe jaw malocclusions to normalise their chewing function and, as such, to improve their quality of life. Over the last few years, digitalisation has been set in motion by intraoral scanners and the improvement of planning software in the field of oral and maxillofacial surgery. Previous studies based on plaster cast models showed that the virtual occlusion based on digitally scanned models can be comparable to conventional methods. This retrospective crossover study aimed to prove that the virtual occlusion finding with the IPS CaseDesigner® (version 2.3.5.2, KLS Martin, Tuttlingen, Germany) is accurate enough to use intraoral scans exclusively. Materials and methodsA total of 23 orthognathic surgery patients receiving an intraoral scan for their treatment were included in this study. Two experienced maxillofacial surgeons haptically performed the occlusion finding on three-dimensional (3D) stereolithographic models using the fully digital pathway. One surgeon repeated the procedure a second time to evaluate intra-observer variability. The study aimed to show the difference between these two planning methods by upholding the surgical accuracy of less than 2 mm in translation and 2° in rotation. The conventional haptic occlusion was set as a reference throughout the whole study. The data were tested with a one-sample Wilcoxon test for the fit into the surgical accuracy. ResultsThe difference between the virtual and conventional groups was significantly smaller than the surgical accuracy (all p < 0.001). Both translational movements (anterior/posterior (median 0.51 mm [0.28, 0.88]), left/right (median 0.46 mm [0.20, 0.87]), cranial/caudal (median 0.37 mm [0.11, 0.69])) and rotations (Roll (median 0.71° [0.29, 1.35]), Pitch (median 0.72° [0.29, 1.44]), Yaw (median 1.09° [0.33, 1.60])) were in the range of surgical accuracy (2 mm/2°). The most significant differences were found in the anterior/posterior translation (median 0.51 mm [0.28, 0.88]) and the Yaw rotation (median 1.09° [0.33, 1.60]). ConclusionThese results demonstrate that the entirely virtual workflow in orthognathic surgery, including intraoral scanning and the virtual semi-automatic occlusion finding, represents a reliable and state-of-the-art alternative to the conventional haptic method.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call