Abstract

An experimental and analytical study was conducted on a fully developed turbulent flow in a square duct, two opposite walls of which had been roughened. The flow was measured by means of a hot-wire anemometer. The calculation was performed with the k model and with the k and e model coupled to the algebraic stress model developed by Launder and Ying. The results of the calculation are compared with the measurements. In this duct, a result hitherto unobserved became apparent: namely, there were four relatively large longitudinal vortices. A prediction of heat transfer was also performed under conditions of a constant wall-temperature and a calculated flow field.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.