Abstract
The authors describe an automatic calibration machine for calibrating internal wind-tunnel balances. The automation is mainly achieved by using a specially designed force measuring device, similar to an external wind tunnel balance. The loading is performed by means of six force generators, according to the six aerodynamic components of the balance. Descriptions are given of the relevant aspects of accuracy, and signal resolution, the mechanical design of the calibration rig, the controlling and safeguarding of the applied forces, and some general aspects of the positioning and alignment of the internal balance to be calibrated. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.