Abstract
ObjectivesTo develop and validate a deep learning (DL) model for automated segmentation of hepatic and portal veins, and apply the model in blood-free future liver remnant (FLR) assessments via CT before major hepatectomy.Methods3-dimensional 3D U-Net models were developed for the automatic segmentation of hepatic veins and portal veins on contrast-enhanced CT images. A total of 170 patients treated from January 2018 to March 2019 were included. 3D U-Net models were trained and tested under various liver conditions. The Dice similarity coefficient (DSC) and volumetric similarity (VS) were used to evaluate the segmentation accuracy. The use of quantitative volumetry for evaluating resection was compared between blood-filled and blood-free settings and between manual and automated segmentation.ResultsThe DSC values in the test dataset for hepatic veins and portal veins were 0.66 ± 0.08 (95% CI: (0.65, 0.68)) and 0.67 ± 0.07 (95% CI: (0.66, 0.69)), the VS values were 0.80 ± 0.10 (95% CI: (0.79, 0.84)) and 0.74 ± 0.08 (95% CI: (0.73, 0.76)), respectively No significant differences in FLR, FLR% assessments, or the percentage of major hepatectomy patients were noted between the blood-filled and blood-free settings (p = 0.67, 0.59 and 0.99 for manual methods, p = 0.66, 0.99 and 0.99 for automated methods, respectively) according to the use of manual and automated segmentation methods.ConclusionFully automated segmentation of hepatic veins and portal veins and FLR assessment via blood-free CT before major hepatectomy are accurate and applicable in clinical cases involving the use of DL.Critical relevance statementOur fully automatic models could segment hepatic veins, portal veins, and future liver remnant in blood-free setting on CT images before major hepatectomy with reliable outcomes.Key PointsFully automatic segmentation of hepatic veins and portal veins was feasible in clinical practice.Fully automatic volumetry of future liver remnant (FLR)% in a blood-free setting was robust.No significant differences in FLR% assessments were noted between the blood-filled and blood-free settings.Graphical
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.