Abstract
The objective of this full‐scale study is to determine the treatment performance of the activated sludge process for treating low strength municipal wastewater. The plant is located in Painesville, Ohio, and discharges its treated effluent into Grand River. The average plant wastewater flow was 3.43 MGD (million gallons per day). The plant performance was evaluated for a 12‐month period in 1989. The low strength municipal wastewater contained 104 mg/L TSS (total suspended solids), 105 mg/L BOD (biochemical oxygen demand), 17.76 mg/L TKN (total kjeldahl nitrogen), 9.66 mg/L NH3‐N, and 3.90 mg/L P (phosphorus). The treatment performance after various degrees of treatment is as follows: primary treatment: 30% BOD and 54% TSS removal, secondary treatment: 97% BOD and 87% TSS removal, and tertiary treatment: 98% BOD and 98% TSS removal. The primary effluent contained 73 mg/L BOD and 48 mg/L TSS; the secondary effluent contained 3 mg/L BOD and 13 mg/L TSS; and the final effluent contained 2 mg/L BOD and 2 mg/L TSS. The effluent contained 0.22 mg/L NH3‐N and 0.49 mg/L P, which were far below the US EPA standard of 10 mg/L BOD, 10 mg/L TSS, 1 mg/L NH3‐N, and 1 mg/L P.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.