Abstract
Herein, a convenient method based on a fullerene/multiwalled carbon nanotube/Nafion modified glassy carbon electrode (fullerene/MWCNT/Naf/GCE) for the electrochemical determination of caffeine (CAF) is reported. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to study ionic exchange properties and conductivity the proposed electrode using [Fe(CN)6]3-/4- redox couple. Caffeine gave an irreversible oxidation peak around +1.33 V (vs. Ag/AgCl reference electrode) in HClO4 (pH 1). The linear dependence of the peak current with the square root of the scan rate showed that the electron transfer process is controlled by diffusion. After optimization of key analytical parameters involved in differential pulse voltammetry (DPV), the oxidation peak current varied linearly with CAF concentration in the range of 10 to 1000 μM. A detection limit of 7.289 × 10-8 M (S/N = 3) was found. Kinetic and chronocoulometric studies were also performed to characterize the diffusion of CAF. The developed electrode exhibited good stability and was easily regenerated. The influence of some potential interfering compounds such as dopamine, uric acid, glucose and sulfite ions on the anodic peak current of CAF was also examined. The proposed method was successfully employed in the determination of CAF in some commercial drugs.
Highlights
The analysis of drugs is of key importance in drug quality control
Several nafion-based composite electrodes were used for the quantification of caffeine, that include nafion/modified boron-doped diamond [21], nafion/carbon nanotube [22], nafion/graphene modified electrode [23], nafion modified carbon electrode [24], nafion/graphite nanoplatelets [25], nafion/attapulgite [26] and nafion-ruthenium oxide pyrochlore modified glassy carbon electrode [27]
On fullerene/MWCNT/Naf/glassy carbon electrode (GCE) the peak current is significantly higher than those registered on the bare GCE and on Naf/GCE
Summary
It is known that a high concentration of caffeine is toxic for the human body: it can cause nausea, trembling, nervousness, depression, hyperactivity and mutation effects [7] [9]. It constitutes a risk factor for cardiovascular diseases and asthma disease [4] [10]. Several effective methods have been developed for the detection and quantification of caffeine in various samples Amongst these methods, the most used are simple chromatographic methods [12] [13] [14], coupled in some cases with mass spectrometry [15] [16]. Several nafion-based composite electrodes were used for the quantification of caffeine, that include nafion/modified boron-doped diamond [21], nafion/carbon nanotube [22], nafion/graphene modified electrode [23], nafion modified carbon electrode [24], nafion/graphite nanoplatelets [25], nafion/attapulgite [26] and nafion-ruthenium oxide pyrochlore modified glassy carbon electrode [27]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.