In this paper we measure for the first time the full-spectral response of a fiber Bragg grating (FBG) sensor subjected to vibration. We consider two cases: with and without an initial spectral distortion due to non-uniform strain along the length of the FBG. Previous work has measured only the dynamic response at a single wavelength which is valid when no spectral distortion is present. FBG sensors are mounted near the notch tip on a double edge notch specimen that is also subjected to harmonic vibration. We measure the full-spectral response of the FBG at 100 kHz applying an interrogator recently developed by the authors. The measurements of the FBG response with an initial spectral distortion clearly show the transient response and are verified through simulation. Finally, we demonstrate that the use of the high-speed, full-spectral interrogator permits the separation of the spectral distortion and the harmonic vibration from the FBG response signal through classical filtering and can therefore be applied to measure non-uniform strain fields in noisy environments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.