The FEMA P-807 Guidelines were developed for retrofitting soft-story wood-frame buildings based on existing data, and the method had not been verified through full-scale experimental testing. This article presents two different retrofit designs based directly on the FEMA P-807 Guidelines that were examined at several different seismic intensity levels. The effects of the retrofits on damage to the upper stories were investigated. The results from the hybrid testing verify that designs following the FEMA P-807 Guidelines meet specified performance levels and appear to successfully prevent collapse at significantly higher seismic intensity levels well beyond for which they were designed. Based on the test results presented in this article, it is recommended that the soft-story-only retrofit procedure can be followed when financial or other constraints limit the retrofit from bringing the soft-story building up to current code or applying performance-based procedures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.