Abstract

Full-scale depressurization tests have been carried out on a riser platform in order to measure outer surface temperatures in the depressurized section of the platform. The tests are performed primarily to find out if the occurring steel temperatures are acceptable during depressurization, and secondly to obtain full-scale experimental data for comparison with the simulation code PIA. Blow-down from two initial pressure levels were tested, 88 and 70 bar. The test section volume was depressurized through a 25 mm nozzle and a pressure of 8 bar was obtained after about 11 and 9 min, respectively. The results of the measurements show that the maximum surface temperature drop is about 9°C at an initial pressure of 88 bar and 6°C at an initial pressure of 70 bar. The lowest outer surface temperature registered was − 4°C. The depressurization tests were also simulated using the finite difference code PIA, and the results for outer wall temperatures are in close agreement with the measurements. Comparisons between heat transfer coefficients used in the simulation code and estimated heat transfer coefficients from the measurements are also in good agreement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.