Abstract

<h3>Background</h3> Cardiac contractility modulation signals are associated with acutely improved hemodynamics, but chronic clinical impact is not defined. <h3>Objectives</h3> The purpose of this randomized, double-blind, pilot study was to determine the feasibility of safely and effectively delivering cardiac contractility modulation signals in patients with heart failure. <h3>Methods</h3> Forty-nine subjects with ejection fraction <35%, normal QRS duration (105 ± 15 ms), and New York Heart Association (NYHA) class III or IV heart failure despite medical therapy received a cardiac contractility modulation pulse generator. Patients were randomized to have their devices programmed to deliver cardiac contractility modulation signals (n = 25, treatment group) or to remain off (n = 24, control group) for 6 months. Evaluations included NYHA class, 6-minute walk, cardiopulmonary stress test, Minnesota Living with Heart Failure Questionnaire, and Holter monitoring. <h3>Results</h3> Although most baseline features were balanced between groups, ejection fraction (31.4% ± 7.4% vs 24.9% ± 6.5%, <i>P</i> = .003), end-diastolic dimension (52.1 ± 21.4 mm vs 62.5 ± 6.2 mm, <i>P</i> = .01), peak VO<sub>2</sub> (16.0 ± 2.9 mL O<sub>2</sub>/kg/min vs 14.3 ± 2.8 mL O<sub>2</sub>/kg/min, <i>P</i> = .02), and anaerobic threshold (12.3 ± 2.5 mL O<sub>2</sub>/kg/min vs 10.6 ± 2.4 mL O<sub>2</sub>/kg/min, <i>P</i> = .01) were worse in the treatment group than in the control group. Nevertheless, one death occurred in the control group, and more patients in the treatment group were free of hospitalization for any cause at 6 months (84% vs 62%). No change in ectopy was observed. Compared with baseline, 6-minute walk (13.4 m), peak VO<sub>2</sub> (0.2 mL O<sub>2</sub>/kg/min), and anaerobic threshold (0.8 mL O<sub>2</sub>/kg/min) increased more in the treatment group than in control. None of these differences were statistically significant (small sample size). NYHA and Minnesota Living with Heart Failure Questionnaire changed similarly in the two groups. <h3>Conclusion</h3> Despite a sicker population in the treatment group, no specific safety concerns emerged with chronic cardiac contractility modulation signal administration. Further study is required to definitively define the safety and efficacy of cardiac contractility modulation signals.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.