Abstract

Recycled-aggregate-concrete (RAC) is mainly used in non-structural elements currently due to its inherent shortcomings from high water absorption rate and weak interfacial transition zones. To extend its structural use, RAC has been combined with FRP tube and steel section in this study to form a new type of composite element: the FRP-confined steel-reinforced concrete (FCSRC) column and the mechanical behavior of the short columns under eccentric compression was investigated. Specifically, the failure modes and stress status based on the strain distributions of the constituent materials of the FCSRC columns were discussed, and their ultimate load capacities were predicted. Test results revealed that the short FCSRC columns with RAC or natural-aggregate-concrete (NAC) exhibited very similar load–strain response except for the ultimate load capacity which was in direct proportion to filament winding angle and steel contribution ratio but inversely proportional to load eccentricity. Besides, the failure modes of the FRP tube were found related to the load eccentricity. The comparisons between test and predicted results indicated that the proposed design calculation model is capable to predict the ultimate load capacity of the FCSRC columns with either RAC or NAC under either concentric or eccentric loads.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.