AbstractIn the last few decades, many destructive earthquakes have taken place all around the world, causing fatal injuries, loss of lives, and severe damages on structures. A number of innovative construction techniques have been developed over the past years to mitigate these casualties. Autoclaved aerated concrete (AAC) is a lightweight, energy efficient building material with satisfactory mechanical properties. Therefore, the use of reinforced AAC panels as load‐bearing structural elements in low‐rise buildings is a potentially viable alternative to traditional construction practices to build cost‐effective structures with adequate seismic performance. In this paper, preliminary results of a number of experimental tests which were executed through a project led by the Turkish Autoclaved Aerated Concrete Association are presented. The experiments include AAC material tests, AAC member tests, and a seismic test of a full‐scale building constructed with AAC panel walls and floors. Finally, design provisions included in the new version of the Turkish Seismic Design Code 2018, which were adopted based on these experimental findings, are outlined.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.