Abstract

A twin-column Multicolumn Countercurrent Solvent Gradient Purification (MCSGP) process has been developed for the purification of a therapeutic peptide, glucagon, from a crude synthetic mixture. This semi-continuous process uses two identical columns operating either in interconnected or in batch mode, thus enabling the internal recycle of the portions of the eluting stream which do not comply with purity specifications. Because of this feature, which actually results in the simulated countercurrent movement of the stationary phase with respect to the mobile one, the yield-purity trade-off typical of traditional batch preparative chromatography can be alleviated. Moreover, the purification process can be completely automatized.Aim of this work is to present a simple procedure for the development of the MCSGP process based on a single batch experiment, in the case of a therapeutic peptide of industrial relevance. This allowed to recover roughly 90% of the injected glucagon in a purified pool with a purity of about 90%.A comparison between the performance of the MCSGP process and the classical single column batch process indicates that percentage increase in the recovery of target product is +23% when transferring the method from batch conditions to MCSGP, with an unchanged purity of around 89%. This improvement comes at the expenses of a reduction of about 38% in productivity.