Abstract
A 7-day-old male infant with membranous pulmonary atresia and intact ventricular septum (PA/IVS) underwent hybrid pulmonary valvotomy. Access was via median sternotomy guided by intra-operative epicardial ultrasonography. After puncturing the atretic pulmonary valve, a 6mm Wanda balloon catheter was inflated to dilate the atretic valve. Adequate valve movement with antegrade flow was confirmed using real time epicardial echocardiography. Intra-operative epicardial ultrasonography is an effective tool for guiding PA/IVS during hybrid procedures. Epicardial echo imaging provides clear images with excellent quality, helps guide the hybrid operation, and prevents the need for the ionizing radiation of fluoroscopy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.