Abstract The stability of precast concrete wall panels under seismic action can be ensured by means of dissipative systems of panel-to-panel connections that allow to control the level of forces and limit the displacements. This paper deals with a connection system consisting of friction-based devices inserted into appropriate recesses within the joints between vertical or horizontal panels. The results of experimental tests carried out on single connectors, as well as on structural sub-assemblies consisting of two full scale panels, are presented. The technological choices of materials and components that ensure a stable hysteretic behaviour of the devices are discussed. The effectiveness of the devices in improving the seismic performance of precast buildings under seismic action is also shown based on the results of cyclic and pseudo-dynamic tests on full-scale structural prototypes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.