Abstract

BackgroundThe objective of this study was to compare the frictional forces generated by three types of monocrystalline ceramic brackets coupled with conventional elastomeric ligatures (CEL) and nonconventional elastomeric ligatures (NCEL) during the alignment of apically displaced teeth at the maxillary arch.MethodsAll tests (a total of 480 tests) were carried out in a dry state on a universal testing machine with a testing model consisting of three 0.022-in. monocrystalline ceramic preadjusted brackets (from the maxillary right second premolar through the right central incisor). The canine bracket was bonded to a sliding bar that allowed for different vertical positions. The frictional forces generated by a 0.012- and 0.014-in. superelastic nickel titanium wire (SENT) with conventional and nonconventional ligatures at various amounts of canine misalignment (1.5, 3.0, 4.5, and 6.0 mm) were recorded. Comparisons between the different types of bracket-wire-ligature systems were carried out by means of analysis of variance on ranks with Tukey's post hoc test (P < 0.05).ResultsNo significant differences were assessed among the three types of monocrystalline brackets with NCEL when coupled with 0.012-in. SENT. Radiance brackets with NCEL coupled with 0.014-in. SENT showed significantly greater frictional force than Inspire Ice brackets and Pure brackets with NCEL. A significantly greater amount of frictional force was generated with CEL when compared with NCEL for all the tested variables, with the exception of the Pure brackets with 0.012-in. SENT at 1.5 and 3.0 mm of canine misalignment where similar frictional forces were found.ConclusionsNonconventional elastomeric ligatures are able to reduce friction in monocrystalline ceramic brackets.

Highlights

  • The objective of this study was to compare the frictional forces generated by three types of monocrystalline ceramic brackets coupled with conventional elastomeric ligatures (CEL) and nonconventional elastomeric ligatures (NCEL) during the alignment of apically displaced teeth at the maxillary arch

  • superelastic nickel titanium wire (SENT), the Inspire Ice brackets with CEL showed a significantly greater frictional force when compared with the Pure brackets with CEL at 1.5 mm

  • At 6.0 mm of canine misalignment, the Radiance brackets with CEL generated a frictional force similar to that of the Inspire Ice brackets with CEL but significantly greater than that produced by the Pure brackets with CEL

Read more

Summary

Introduction

The objective of this study was to compare the frictional forces generated by three types of monocrystalline ceramic brackets coupled with conventional elastomeric ligatures (CEL) and nonconventional elastomeric ligatures (NCEL) during the alignment of apically displaced teeth at the maxillary arch. Nonconventional elastomeric ligatures (NCEL) have been proposed to reduce frictional resistance in treatment mechanics with preadjusted fixed appliances These ligatures can be used on any type of conventional brackets, esthetic brackets included [9,10,11,12]. The aim of this in vitro study was to analyze the frictional forces released during the leveling and aligning phase of fixed appliance therapy by three types of monocrystalline ceramic brackets with conventional elastomeric ligatures (CEL) compared with nonconventional elastomeric ligatures (NCEL) at different amounts of vertical canine misalignment

Objectives
Methods
Results
Conclusion