Abstract
The experimental friction factor and Nusselt number data for a laminar flow through a circular duct having axial corrugation and fitted with helical screw-tape inserts have been presented. Predictive friction factor and Nusselt number correlations have also been presented. The thermohydraulic performance has been evaluated. The major findings of this experimental investigation are that the helical screw-tape inserts, in combination with axial corrugation, perform better than the individual enhancement technique acting alone for laminar flow through a circular duct.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.