Abstract

Measurements are reported of overall test section friction and of local heat transfer for the case in which hydrodynamically developed turbulent flow of water enters a uniformly heated circular tube. Systematic data are given for various heating rates and are shown to extrapolate to the zero heating rate or constant fluid property condition. In the thermal entrance region, variable property results are shown to agree with the measurements of Hartnett and constant property results are shown to agree with the analytical results of Sparrow, Hallman, and Siegel. Variable property test section friction results are shown to follow the wall temperature rule of Eagle and Ferguson. Constant property heat-transfer results at Pr = 8 are shown to yield a Reynolds number exponent which increases systematically from 0.84 at Re = 15,000 to 0.87 at Re = 100,000. Nusselt numbers at Pr = 8 are in excellent agreement with the analytical results of Sparrow, Hallman, and Siegel.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.